| Structural fields |
| idx |
integer |
Unique index number for each run, automatically assigned |
| name |
string |
Descriptive name for this scenario |
| Deprecated fields |
| comment |
string |
These fields have all been replaced with new ways of doing things. |
| constraints |
integer |
|
| oldcons |
integer |
|
| newsams |
integer |
|
| Run parameter fields |
| min |
integer |
minimum number of racks/facilities to select |
| max |
integer |
maximum number of racks/facilities to select |
| numcombos |
integer |
number of combinations at each number of racks/facilities, usually 1000 |
| tblname |
string |
name of the table to store the output data in |
| outputdb |
string |
name of the database tblname is in |
| outputpath |
string |
where to put the charts for this run inside the PLUM output directory. |
| topology |
string |
name of the rack topology to use, links to name in topology table |
| ignorezeros |
boolean |
if this is true, then resources with a zero capability never exceed no matter what the total usage is. |
| Resource fields |
| MLE |
number |
|
| stowage |
number |
|
| upmass |
number |
|
| bulk |
number |
|
| rack_overhead |
number |
|
| crewtrng |
number |
|
| crewtime |
number |
|
| power |
number |
|
| keepalive |
number |
|
| Networking fields |
| avg_uplink |
number |
|
| avg_ethernet |
number |
|
| avg_1553 |
number |
|
| avg_HRL |
number |
|
| avg_downlink |
number |
|
| peak_uplink |
number |
|
| peak_ethernet |
number |
|
| peak_1553 |
number |
|
| peak_HRL |
number |
|
| peak_downlink |
number |
|
| peak_uplink_duration |
number |
|
| peak_downlink_duration |
number |
|
| peak_1553_duration |
number |
|
| peak_ethernet_duration |
number |
|
| peak_HRL_duration |
number |
|
| video_uplink |
number |
|
| video_downlink |
number |
|
| video_rate |
number |
|
| Constant fields |
| inclength |
number |
the number of days in an increment. Usually 90 or 180. |
| middeckmass |
number |
|
| passiveMLE |
number |
|
| passive_middeck_mass |
number |
|
| sams_power |
number |
The power usage of SAMS. Added to the power requirement of the rack containing SAMS. |
| hskpg |
number |
|
| ku_power |
number |
|
| pl_power |
number |
|
| stowage_MLEs |
number |
|
| Cold stowage fields |
| cs_p4_asc |
number |
|
| cs_p4_orb |
number |
|
| cs_p4_desc |
number |
|
| cs_m20_asc |
number |
|
| cs_m20_orb |
number |
|
| cs_m20_desc |
number |
|
| cs_m80_asc |
number |
|
| cs_m80_orb |
number |
|
| cs_m80_desc |
number |
|
| cs_m180_asc |
number |
|
| cs_m180_orb |
number |
|
| cs_m180_desc |
number |
|